请问ul 1007 22号线 能允许通过的最大电流是多少 有没有一个大概估算的方法

如题所述

导 体 绝 缘 体 (Conductor) (Insulation) UL1007CSATR-64 额 定Range 导体Conductor 绝缘体Insulation公差值Tolerancemm 最大导体 阻 抗Maximum Conductor ResistanceΩ/km 容许电流PermitableCurrentA 绝缘耐 电压(VAC/min)InsulationPotentialStrength 温度 Temp℃ 电 压VoltageV 线号AWG 构成NO./mm 厚度Thicknessmm 外径O.Dmm 多芯线 StrandedUL80℃ CSA90℃ 300V 327/0.0800.381.00±0.10703.01.602000 307/0.1000.381.10±0.10397.02.00287/0.1270.381.20±0.10248.02.50267/0.1600.381.30±0.10152.03.502411/0.1600.381.45±0.1088.605.002217/0.1600.381.60±0.1062.507.002021/0.1800.381.85±0.1039.509.001834/0.1800.382.10±0.1024.4013.01626/0.2540.382.40±0.1015.6017.0先绞後镀 Top-Coated (ATC) UL80℃CSA90℃300V 307/0.1000.381.10±0.10397.02.00287/0.1270.381.20±0.10248.02.50267/0.1600.381.30±0.10152.04.00247/0.2000.381.45±0.1088.605.30227/0.2540.381.60±0.1062.507.20207/0.3200.381.85±0.1039.5010.0单芯线 Solid(TA)UL80℃ CSA90℃ 300V 281/0.3200.381.15±0.10232.12.90261/0.4040.381.25±0.10155.03.80241/0.5110.381.40±0.1092.405.30221/0.6430.381.55±0.1060.107.20201/0.8130.381.70±0.1037.009.4018 多芯线7a 单芯先绞后镀后7.2a
温馨提示:内容为网友见解,仅供参考
第1个回答  2020-12-09
UL1007电子线,电器内部配线,定电压300V,温度范围:-30度-+80度,导体:单股或多股绞合裸铜或镀锡铜线导体,绝缘体:PVC(聚氯乙烯)
导体大小从32AWG-16AWG 导体截面积从0.03平方到1.3平方,
具体电流你可以参考安全电流在0.44A

  最大极限在0.7A

  计算公式:铜丝面积*5《通过电流《铜丝面积*8;

  电子线1007英文为:ELECTRIC WIRE 1007,一般是用于弱电工程,如电子、电器设备内部连线等。目前,在生产电子线领域,国内大型电子线生产企业是东莞市胜牌电线电缆有限公司(前身为承兴电线CHENG XING E249743)。
第2个回答  2013-10-12
3A左右,这个没有一个估算方法。但有些电流、线规对应表格可以作为参考。
第3个回答  2015-08-11
UL1007电子线,电器内部配线,定电压300V,温度范围:-30度-+80度,导体:单股或多股绞合裸铜或镀锡铜线导体,绝缘体:PVC(聚氯乙烯
导体大小从32AWG-16AWG 导体截面积从0.03平方到1.3平方,
具体电流3A左右,这个没有一个估算方法。但有些电流、线规对应表格可以作为参考。
相似回答